LG Refrigerators

Error Code E rt

Room temperature (ambient) sensor error — short-circuit or disconnection of RT sensor

Moderate

Address soon - your appliance may not work properly

Also displayed as: E rt

How to Fix

  1. 1

    Check for loose or disconnected connector between Main PCB and RT sensor.

  2. 2

    Measure sensor resistance and compare to expected value for ambient temperature.

  3. 3

    If resistance is 0 Ω (shorted) or infinite (open), replace the RT sensor.

  4. 4

    If sensor checks out, replace Main PCB.